Engine System
15
Service Manual – PBU Propane Floor Burnisher
Maintenance and Adjustments
This section includes maintenance and adjustment procedures associated with routine maintenance
Additional procedures are located within the mechanical sections of this chapter
Maintenance Specifications
The table below contains a quick reference for common maintenance parameters Also refer to the complete
Quick Reference Parameters
Parameter
Value
Reference
Low Idle Speed
1800 - 2000 rpm
High Idle Speed
3400 - 3450 rpm @ 21”
3450 - 3550 rpm @27”
Oil Grade
SJ or higher
Viscosity
SAE 30
Capacity w/o filter
1.5L (1.6 US qt)
Capacity w/ filter
1.7L (1.8 US qt)
Spark Plug
NGK BPR4ES
Spark Plug Gap
0.6 mm (0.025 in)
Spark Plug Torque
22 N
•
m (16 ft
•
lb)
Coil Air Gap
0.2 - 0.4 mm
(0.008 - 0.016 in.)
Valve Clearance
0.10 - 0.15 mm
(0.004 - 0.006 in.)
Min. Cyl. Compression
483 kPa (70 psi)
Cooling Air Filter
The cooling filter should be cleaned every 1 engine-hour.
It is also a good practice to clean the cooling air filter
when ever the machine is serviced Restrictions in the
airflow can result in the engine to run hotter than normal.
1
Carefully pull the filter off the top of the engine,
taking care not to damage the Velcro fasteners
2
Brush off large debris from the filter surface.
3
The filter may be washed with light detergent (dish
soap) and water
4
Squeeze out excess water. Do not wring the filter as
this can tear the foam or damage the Velcro tabs
5
Set the filter aside to dry before reinstalling it.
Cooling
Filter
Hook and
Loop Tabs
New & Reconditioned Equipment & Parts- www.southeasternequipment.net
New & Reconditioned Equipment - www.southeasternequipment.net