Solution System
142
Service Manual – SC6500
™
The
Solution Control Pump M12
and solution
Solenoid Valve L1
are connected to battery ground through the
A2
Control Board Assembly
. The
A2 Control Board Assembly
connects the
Solution Control Pump M12
and solution
Solenoid Valve L1
to ground to run the
Solution Control Pump M12
and switch on the
Solenoid Valve L1
when:
• The
A3 Switch/Display Panel Assembly
sends the
A2 Control Board Assembly
a signal via the CAN BUS that
the solution system has been enabled, and,
• The
A1 Speed Controller
sends the
A2 Control Board Assembly
a signal that the wheel drive is switched on.
Note that you can select whether the solution system will switch on when the machine is moving in both
forward and reverse, or when moving forward only. This option is described in the
Control System/Main
Control Programming Options
section.
Note that the ground voltage from the
A2 Control Board Assembly
to the
Solution Control Pump M12
is pulse-
width-modulated (PWM) voltage that varies in frequency to control the solution flow from the
Solution
Control Pump M12
. The ground voltage from the
A2 Control Board Assembly
to the
Solenoid Valve L1
is also
PWM voltage, but is always at full voltage when the
Solution Control Pump M12
is on.
Detergent System
The
Detergent Metering Pumps M13
and
M16
are powered directly by the
A2 Control Board Assembly
. The
A2
Control Board Assembly
sends the
Detergent Metering Pumps
voltage to run the
Detergent Metering Pumps
when:
• The
A3 Switch/Display Panel Assembly
sends the
A2 Control Board Assembly
a signal via the CAN BUS that
the detergent system has been enabled, and,
• The solution system is switched on.
Note that the voltage from the
A2 Control Board Assembly
to the
Detergent Metering Pumps
is PWM voltage
that varies in frequency to control the detergent flow from the
Detergent Metering Pumps
into the solution
system.
Accessory Pump
The
Accessory Pump M15
gets positive voltage from the
Battery
when the load side of contactor
K5
is closed.
When the internal
Accessory Pump
pressure switch is closed, it connects the negative side of the
Pump
motor
to battery ground. The pressure switch works as follows:
• When the wand trigger is pressed and the pressure in the wand solution hose drops to a predetermined
level, the pressure switch switches on the
Accessory Pump
.
• When the wand trigger is released, the
Accessory Pump
will continue to run momentarily. When the
pressure in the wand solution hose increases to a predetermined level, the pressure switch switches off
the
Accessory Pump
.