Wheel System, Traction
199
Service Manual – SC6500
™
Troubleshooting Chart
Flash
Code
#
Programmer LCD
Display
/ Effect Of Fault
Possible Cause(s)
Set
/
Clear
Conditions
87
Motor Characterization
Fault
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake; ShutdownPump.
1. Motor characterization failed
during characterization
process. See Monitor
menu » Controller: Motor
Characterization Error for
cause:
0=none
1=encoder signal seen, but
step size not determined;
set
Encoder Step Size manually
2=motor temp sensor fault
3=motor temp hot cutback
fault
4= controller overtemp cutback
fault
5=controller undertemp
cutback fault
6=undervoltage cutback fault
7=severe overvoltage fault
8=encoder signal not seen, or
one both channels missing
9=motor parameters out of
characterization range.
Set
: Motor characterization
failed during the motor
characterization process.
Clear
: Correct fault; cycle KSI.
88
Encoder Pulse Error
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD; FullBrake;
ShutdownPump.
1. Encoder Steps parameter does
not match the actual motor
encoder
Set
: Motor lost IFO control and
accelerated without throttle
command.
Clear
:
Ensure the Encoder
Steps parameter matches the
actual encoder; cycle KSI.
89
Motor Type Fault
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake; ShutdownPump.
1. The Motor_Type parameter
value is out of range.
Set
: Motor_Type parameter is
set
to an illegal value.
Clear
:
Set
Motor_Type to
correct value and cycle KSI.