General Information
26
Service Manual – SC6500
™
–
The indicator will be off when the scrub system is switched off and the brooms are in the raised
position.
•
EcoFlex Indicator:
–
The (green) indicator will be on when the EcoFlex
™
low-concentration detergent mode is enabled.
–
The (green) indicator will flash when the EcoFlex
™
burst of power mode is enabled.
–
The (green) indicator will be off when the EcoFlex
™
full-concentration detergent mode is enabled.
Note:
When the recovery tank becomes full (when in the auto scrub mode), the vacuum motors and
all other systems shut off except the drive motor. The LCD on the dash panel will display the
full tank icon.
Control Panel Display
The control panel display is a liquid
crystal display (LCD) that shows the
hour meter, battery charge indicator,
solution flow rate and scrub pressure.
If the detergent system is enabled, the
display will also show the detergent
system indicator and the current
detergent/solution ratio.
If an A2 Control Board error occurs,
the display will show a wrench icon
to indicate an error, and display a
two-digit error code number. If more
than one error exists, the display will
sequence through the error codes at
one-second intervals. (Refer to the
Control System
section for a list of the
A2 Control Board error codes.)
Caution Displays
If the recovery tank is full, the display will show a caution symbol
and the tank full icon.
If the battery charge level falls to a critical level, the display will
show a caution symbol and the battery-low icon.
Ø.4
Ratio
Hour
Meter
Detergent
System
Indicator
Battery
Indicator
Heavy
Scrub
Pressure
Normal
Scrub
Pressure
Extreme
Scrub
Pressure
Heavy
Solution
Flow
Regular
Solution
Flow
Extreme
Solution
Flow
Error
Indicator
29
Error
Code
Number
!
!