General Information
27
Service Manual – SC6500
™
Circuit Breakers
The machine circuit breakers are located on the panel to
the left of the Operator seat.
General Maintenance
Maintenance After Use
1. When finished scrubbing, press the Scrub Off Switch. This will automatically raise the scrub deck and
squeegee, and switch off the solution, detergent and vacuum systems.
2. Drive the machine to a service area for daily maintenance, and check the machine for any additional
maintenance or service that may be needed.
3. To empty and clean the solution tank:
a.
Remove the
Solution Tank Drain
Hose
from its storage clamp.
b. Direct the
Solution Tank Drain Hose
to a designated disposal site and
remove the
Solution Tank Drain
Hose Plug
.
c.
Rinse the tank with clean water.
4. To empty and clean the recovery tank:
a.
Pull the
Recovery Tank Drain Hose
from its storage area.
b. Direct the
Recovery Tank Drain
Hose
to a designated disposal site
and remove the
Recovery Tank
Drain Hose Plug
. (Hold the end of
the
Recovery Tank Drain Hose
above
the water level in the tank to avoid
sudden, uncontrolled wastewater
flow.) The
Recovery Tank Drain Hose
can be squeezed to regulate the
flow.
c.
Rinse the recovery tank with clean
water.
Solution Tank
Drain Hose
Solution Tank
Drain Hose Plug
Recovery Tank
Drain Hose
Recovery Tank
Drain Hose Plug
Vacuum
Hose
Hopper