Recovery System
98
Service Manual – SC6500
™
3. Install a one inch open-hole adapter between the hose end
and the vacuum gauge.
4. Turn the vacuum motor on and measure the vacuum. If it
is within 10% of the specs, the vacuum system is working
properly. If the reading is too low, check for a restriction in