Sweep System, Side Broom
167
Service Manual – SC6500
™
Circuit Description
The coil side of contactor
K6
gets positive voltage from the
Battery
when the load side of contactor
K5
is
closed. Contactor
K5
closes when the
A2 Control Board Assembly
connects the
K5
coil to battery ground.
Contactor
K6
is connected to battery ground through the
A2 Control Board Assembly
.
The
Side Broom Motors M7
and
M8
get positive voltage from the
Battery
when the load side of contactor
K6
is
closed. Contactor
K6
closes when the
A2 Control Board Assembly
connects the
K6
coil to battery ground. The
Side Broom Motors M7
and
M8
are connected directly to battery ground.
The
Side Broom Actuator M4
gets voltage from the
A2 Control Board Assembly
which switches the polarity to
move the side brooms up or down. When the
A2 Control Board Assembly
receives a signal from the
A3 Switch/
Display Panel Assembly
via the CAN BUS that the operator has pressed the scrub on switch, the
A2 Control
Board Assembly
sends the appropriate voltage to the
Side Broom Actuator M4
to lower the side brooms to the
operating position.
Component Locations
The
Side Broom Assemblies
are
mounted onto the
Side Broom
Bracket Weldments
using parallel
Links
, sleeve bearings, bushings
and fasteners.
The
Side Broom Lift Actuator
is
mounted horizontally is attached
to the machine frame and
Lift Arm
with clevis pins. The
Lift Arm
is
connected via short chains to the
Side Broom Assemblies.
As the
Side
Broom Lift Actuator
retracts and
extends, it pivots the
Lift Arm
to
raise and lower the
Side Broom
Assemblies
.
Side Broom
Bracket
Weldment (2)
Side Broom
Assembly (2)
Link (4)
Lift
Arm
Side Broom
Lift Actuator