Control System
35
Service Manual – SC6500
™
To Select the Battery Used in the Machine
Note that the factory default is Standard (LVC = 31V)
1. Turn the key switch off.
2. Press and hold the scrub off switch.
3. While holding the scrub off switch, turn the key switch on.
4. Continue to hold the scrub off switch until the Scrub Off LED indicator turns on.
5. Release the switch. The display will now show BATTERY.
6. Press the scrub on switch to select the type of battery that is in the machine.
7. Press the scrub off switch to save the new setting and display the key switch icon.
8. Turn the key switch off. The new setting will be saved until changed again.
To Restore the Scrub Pressures to the Factory Default Settings
1. Turn the key switch off.
2. Press and hold the scrub on switch.
3. While holding the scrub on switch, turn the key switch on.
4. Continue to hold the scrub on switch until the display shows key switch icon. The factory default scrub
pressures have now been restored.
5. Turn the key switch off.
To Enable/Disable the Fault Detection
Note that the factory default for fault detection is OFF.
You can enable or disable “open circuit” fault detection with this setting. If the setting is set to “off” the
controller will still detect and set faults for over current conditions.
To turn the fault checking on or off:
1. Turn the key switch off.
2. Press and hold both the scrub off switch and solution switch.
3. While holding both switches, turn the key switch on.
4. Continue to hold both switches until both switch indicators turn on. The display will show a wrench icon
indicating fault detection mode.
5. Release both switches. The solution system indictor light will blink and the scrub off indicator will stay
on.
6. Press the solution switch to toggle the fault detection between enabled/on (wrench icon with no cross) or
disabled/off (wrench icon with cross).
7. Press the scrub off switch to save the new setting and display the key switch icon.
8. Turn the key switch off. The new setting will be saved until changed again.