Recovery System
95
Service Manual – SC6500
™
Maintenance
Warning! Before performing any machine maintenance or adjustments, make sure the key
switch is off, the key is removed from the machine and the parking brake is engaged.
To Inspect and Clean the Vacuum Filter and Inlet Screen
1. Open the tethered
Vacuum Filter Lid
.
2. Remove the
Filter
and
Filter Screen
by pulling them
out of the recess in the
Recovery Tank Top
.
3. Clean the
Filter
and
Filter Screen
with vacuum or by
washing them in warm water.
4. When the
Filter
and
Filter Screen
are clean and dry,
reinstall them into the
Recovery Tank Top
.
Service Note:
The
Filter
and
Filter Screen
must be completely dry before
reinstalling.
5. Replace the
Vacuum Filter Lid
.
To Inspect and Clean the Vacuum Motor Float
Cage
1. Lift the
Recovery Tank Lid
to access the
Float Cage
and
captive float ball. The
Float Cage
is attached to the
underside of the
Top Cover Assembly
.
2. Carefully remove the
Float Cage
from the
Top Cover
Assembly
. Note that the
Float Cage
is a two-piece
design and can be snapped apart to separate for
cleaning.
3. Clean any debris from the
Float Cage
slots with a rag,
or by flushing the
Float Cage
with water. The
Float
Cage
slots must be kept clean to prevent any airflow
restriction.
4. Reassemble the
Float Cage
and captive float ball and
reinstall into the
Top Cover Assembly
.
5. Inspect the
Recovery Lid Gasket
to make sure it is not
damaged and is sealing correctly.
Vacuum
Filter Lid
Filter
Filter
Screen
Recovery
Tank Top
Recovery
Tank Lid
Float
Cage
Top Cover
Assembly
Recovery
Lid
Gasket