ELECTRICAL SYSTEM
76
Service Manual – Advenger, 2800ST, 3800ST, BR 755, BR 855
Rev Measurements
The information in the following tables was taken from measuring a single machine with a REV deck. These
values will vary from machine to machine based on battery charge level etcc., however, they will still give
you a picture of what normal should look like. Battery Negative used used for the black voltmeter lead and
each pin location was back-probed with the red voltmeter lead unless otherwise specified.
Connector J1
Pin
Wire
Circuit
Measured
Comment
1
RED/YEL
Detergent Pump
2.05v Key on
2
-
3
BLU/GRY
Detergent Pump
2.08v Key on
4
BLU
Deck Actuator
1.9v rest
24v Down
0.3v Up
5
ORN/BLK
Deck Actuator
2.0v rest
24v Up
0.3v Down
6
-
7
-
8
YEL/BLK
B- for Act. Pos.
Switches
0.06v
Vacuum On
9
BLK/YEL
Squeegee Actuator
2.1v Rest
0.3v down
24.1 Up
10
WHT/GRN
Squeegee Actuator
2.1v Rest
0.3v down
24.1 Up