FORM NO. 56043025 / BA 700, 800, 1000 / 28LX, 32LX, 38LX / 280HD, 320HD, 380HD -
15
SOLUTION SYSTEM
N
M
O
FRONT
W
T
X
U
V
R
Q
S
P
______________________________________________________________________________________________
SOLUTION SOLENOID VALVE REMOVAL - BA 700 / 28LX / 280HD
1
Drain the solution and recovery
tanks at a designated “DISPOSAL
SITE” and disconnect one of the
battery cables.
2
Tip the solution tank over to the
side of the machine.
3
See Figure 6. Remove the (4)
(M)
Screws and remove Cover
(N)
from
the machine.
4
See Figure 7. Disconnect Hoses
(O)
,
(P)
,
(Q)
and then disconnect
the solenoid valve wiring connec-
tor.
FIGURE 6
FIGURE 7
5
Remove the (2)
(R)
Screws, remove the Solenoid Valve
(S)
and Bracket
(T)
from the machine.
6
Remove the fittings from the solenoid valve only if you are replacing the solenoid valve (remove Fittings
(U)
,
(V)
,
(W)
,
and
(X)
as a one piece unit to avoid snapping them off inside the Tee Fitting
(X)
.
7
Reassemble in reverse order and test for leaks and proper operation.