32
- FORM NO. 56043025 / BA 700, 800, 1000 / 28LX, 32LX, 38LX / 280HD, 320HD, 380HD
VACUUM SYSTEM
FRONT
BA 700 After SN 1082068
BA 800, BA 1000 After SN 1081110
All 28LX / 280HD
All 32LX, 38LX / 320HD, 380HD
Vac Motor
Circuit Breaker
Vac Motor
Solenoid
FRONT
BA 700 Before SN 1082069
BA 800, BA 1000 Before SN 1081111
Vac Motor
Circuit Breaker
Vac Motor Solenoid
______________________________________________________________________________________________
Problem:
Vacuum motor will not run when squeegee is lowered
Possible Cause & Remedy:
1
Tripped vacuum motor circuit breaker (see Figures 8A and 8B) — press reset button, check circuit breaker for
continuity.
2
Defective vacuum switch (see Figure 9) — remove cover panel from back of control handle, adjust or replace switch.
3
Defective vacuum motor — remove motor, repair or replace.
4
Defective vacuum motor solenoid (see Figures 8A and 8B)— replace solenoid.
_____________________________________________________________________________________________________________________________
TROUBLESHOOTING (continued)
FIGURE 8A
FIGURE 8B
FIGURE 9
Vacuum
Switch