A-6
- FORM NO. 56041805 - BR 850S SBG SPECIAL
A-6 / ENGLISH
DESCRIPTION OF THE BATTERY CONDITION INDICATORS
The battery condition indicator
(K)
consists of three lights, a green, a yellow, and a red. The voltage indication will change based on the cutoff level (standard
or alternate) selected in the control unit. The battery voltage ranges for the various indications are listed below:
Standard
Alternate
Green 34.00+ 34.50+
Green & Yellow
33.00-33.99
34.00-34.49
Yellow 32.00-32.99
33.50-33.99
Yellow & Red
31.50-31.99
33.00-33.49
Red 31.00-31.49
32.50-32.99
Flashing Red/Cutoff
<31.00
<32.50
NOTE:
Refer to service manual for selection of alternate cut-off level. Once the low voltage cutout level has been reached (
fl
ashing red indicator) the
batteries must be
FULLY
recharged to reset the battery condition indicator. The scrub system will not function until the indicator has been reset.
INSTALL THE BATTERIES
WARNING!
Use extreme caution when working with batteries. Sulfuric acid in batteries can cause severe injury if allowed to contact the skin
or eyes. Explosive hydrogen gas is vented from inside the batteries through openings in the battery caps. This gas can be ignited
by any electrical arc, spark or
fl
ame.
When Servicing Batteries...
*
Remove all jewelry.
*
Do not smoke.
*
Wear safety glasses, a rubber apron and rubber gloves.
*
Work in a well-ventilated area.
*
Do not allow tools to touch more than one battery terminal at a time.
CAUTION!
Electrical components in this machine can be severely damaged if the batteries are not installed and connected properly.
Batteries should be installed by Nil
fi
sk or by a quali
fi
ed electrician.
1
Turn the Key Switch
(J)
off (O) and remove the key. Then swing open the Battery Compartment Cover
(16)
.
2
Using (2) people and an appropriate lifting strap, carefully lift the batteries into the compartment tray exactly as shown. Refer to decal 56380513 battery
cable layout.
3
See Figure 1.
Install battery cables as shown and tighten the nuts on the battery terminals.
4
Install the battery boots and secure tightly to the battery cables with the supplied tie straps.
5
Connect the battery pack connector to the machine connector
(22)
and close the battery compartment cover.
FIGURE 1