Changing the HEPA fi lter
The HEPA
fi
lter cleans the exhaust air
from micro particles the dust bag can
not keep. The HEPA
fi
lter can not be
brushed or washed clean.
1. Open the lid on the machine in the
back.
2. Remove the blow function lid.
3. Take out the HEPA
fi
lter.
4. Insert the new HEPA
fi
lter. Check
that the HEPA
fi
lter is correctly
fi
tted.
5. Put the blow function lid back.
6. Put the lid back and close.
Adjust the suction power
Sliding valve on the bent tube
The suction power is maximal with the
sliding valve closed and minimal when
all open. Adjust the suction power by
putting the sliding valve in the desired
position.
Power regulation
The suction power is adjusted on the
power regulator.
Parking the tube and nozzle
There are two grooves for parking.
One located on the underside to use
when machine stands on the back,
and the other on the back to use when
the machine is standing on its wheels.
5
6
Thermal fuse
The machine is
fi
tted with a thermal
fuse, which prevents the machine from
overheating. If the thermal fuse blows,
the machine automatically switches off
the motor and must cool before it can
be started again.
Restart
1. Turn off the machine and unplug
from the wall socket.
2. See to that nothing blocks the air
fl
ow through the bent tube, hose,
tube, nozzle, dust bag or
fi
lters.
3. Let the machine cool.
4. Plug in the machine again and
push the start button. The machine
will not start until cool enough. If
the machine does not start turn it
off and unplug. Try again in a while.