background image

 5

 - FORM NO. 56041431 / GW 4512, GW 6016

INTRODUCTION

This manual will help you get the most from your 

Advance GW 4512/6016

.

Read it thoroughly before operating the machine.

Note: Bold numbers in parentheses indicate an item illustrated on page
1 (Figure A).

This product is intended for commercial use only.

PARTS AND SERVICE

Repairs, when required, should be performed by your Authorized Advance
Service Center, who employs factory trained service personnel, and maintains
an inventory of Advance original replacement parts and accessories.

Call the ADVANCE DEALER named below for repair parts or service.  Please
specify the Model and Serial number when discussing your machine.

(Dealer, affix service sticker here.)

NAME PLATE

The Model and Serial Number of your machine are shown on the Nameplate on
the machine.  This information is needed when ordering repair parts for the
machine.  Use the space below to note the Model and Serial Number of your
machine for future reference.

MODEL

SERIAL NUMBER

UNCRATING

When the machine is delivered, carefully inspect the shipping carton and the
machine for damage.  If damage is evident, save the shipping carton so that it
can  be  inspected.    Contact  the  Advance  Customer  Service  Department
immediately to file a freight damage claim.

MACHINE ASSEMBLY

1

After uncrating, loosen the Handle Adjustment Knobs 

(12)

 and swing the

Handle 

(7)

 upright to a comfortable position.

2

If you have an Air Scoop model, install the Squeegee 

(9)

, Recovery Hose

(8)

 and Hose Adapter 

(13)

 as shown in Figure A.

3

If you have a non Air Scoop model, simply install the Hose Adapter 

(13)

a recovery hose and whatever attachments you wish to use.

A - KNOW YOUR MACHINE

1

Main Power Switch

2

Power Head

3

Recovery Tank / Chassis

4

Squeegee Raise / Lower Pedal (Air Scoop only)

5

Drain Hose

6

Power Cord

7

Handle

8

Recovery Hose (Air Scoop only)

9

Squeegee (Air Scoop only)

10

Power Head Handle

11

Power Head Latches

12

Handle Adjust Knobs

13

Hose Adapter

14

Bucket (100V only)

TO PICK UP WATER

1

If the machine has been used for dry pick-up, remove the Dry Pick-Up
Filter 

(A)

 and re-install the Float 

(B)

 (See Figure B, page 1).

2

Place the Power Head 

(2)

 on top of the Recovery Tank / Chassis 

(3)

 and

Latch 

(11)

 into place.  Make sure that the Main Power Switch 

(1)

 is in the

OFF position, then plug the Power Cord 

(6) 

into a wall outlet.

3

If you have an Air Scoop model, re-attach the Squeegee 

(9)

 and the

Recovery Hose 

(8)

.  If you have a non Air Scoop model, re-attach the

recovery hose.

4

Connect the other end of the Recovery Hose 

(8)

 to the Squeegee 

(9)

 or

wand  and  wet  pick-up  tool.    Accessory  hoses,  wands  and  other
attachments are available from your local Advance Dealer.

5

Turn the Main Power Switch 

(1)

 ON.

6

Release the Squeegee Raise/Lower Pedal 

(4)

 to lower the Squeegee

(9)

 to the floor.  The Squeegee will pick up while moving forward or in

reverse.  

(This step applies to the Air Scoop model only).

7

Add  a  defoamer  chemical  when  picking  up  soapy  water.    To  add
defoamer, first turn the Main Power Switch

 (1)

 OFF.  Then remove the

Power Head 

(2)

 and pour the defoamer chemical into the Recovery

Tank / Chassis 

(3)

, Bucket 

(14)

 on 100V model

.

  See the manufacturer’s

recommendations for the proper amount.  Put the Power Head 

(2)

 back

on the Recovery Tank / Chassis 

(3)

, Latch 

(11)

 into place and turn the

Main Power Switch 

(1)

 ON

.

  Add defoamer each time the tank (bucket)

is emptied.

8

The Power Head 

(2)

 has an automatic float shutoff to block the vacuum

system when the tank is full.  You can tell when the float closes by the
sudden  change  in  the  sound  of  the  vacuum  motor.    When  the  float
closes, the tank (bucket) must be emptied.  The machine will not pick up
water with the float closed.

TO PICK UP DUST AND DIRT

1

If the machine has been used for wet pick-up, empty the Recovery Tank
/  Chassis 

(3)

,  Bucket 

(14)

  on  100V  model,  rinse  it  out  and  dry  it

completely and install the Dry Pick-Up Filter (See Figure B).  To install
the Dry Pick-Up Filter, first pull the Float 

(B)

 (Figure B) off of the Power

Head 

(2)

.  The Float 

(B)

 is held in place by rubber retainers and can be

pulled off and pushed back on easily.  Push the Dry Pick-Up Filter 

(A)

onto the vacuum motor housing as shown in Figure B (the filter fits
snugly over the vacuum motor housing, friction fit).

NOTE:

  DO NOT use the machine for dry pick-up without the Dry Pick-

Up Filter 

(A)

 (Figure B) in place.

2

Re-install the Power Head 

(2)

 on top of the Recovery Tank / Chassis 

(3)

and Latch 

(11)

 into place.

3

Connect the other end of the hose to a wand fitted with a dry pick-up tool.
Accessory hoses, wands and other attachments are available from your
local Advance Dealer.

4

Plug the Power Cord 

(6) 

into a wall outlet and turn the Main Power Switch

(1)

 ON.

revised 5/99

Summary of Contents for GW 4512

Page 1: ...12 98 revised 10 99 Form Number 56041431 GW 4512 GW 6016 OPERATOR MANUAL Advance MODELS 56209801 56209803 56209806 56209809 56209802 56209805 56209807 56209813 56210000 ...

Page 2: ...S DE SÉCURITÉ 3 120VAC GROUNDING INSTRUCTIONS 4 INSTRUCTIONS VISANT LA MISE À LA TERRE 120VAC 4 Introduction 5 Machine Assembly 5 Know Your Machine 5 To Pick Up Water 5 To Pick Up Dust And Dirt 5 After Use Wet Pick Up 6 After Use Dry Pick Up 6 Lubrication 6 Vacuum Motor Brushes 6 Maintenance Schedule 6 Technical Specifications 6 ...

Page 3: ...d sharp edges or corners Do not run the appliance over the cord Keep the cord away from heated surfaces Do not unplug by pulling on the cord To unplug grasp the plug not the cord Do not handle the plug cord or appliance with wet hands Donotputanyobjectintoopenings Donotusewithanyopeningblocked keepfreeofdust lint hair andanythingthatmayreduce air flow Keep loose clothing hair fingers and all parts...

Page 4: ...il sur le cordon Gardez le cordon à l écart de toutes surfaces chaudes Ne débranchez pas l appareil en tirant sur le cordon Pour débrancher empoignez la prise pas le cordon Ne touchez pas à la prise au cordon ou à l appareil avec des mains mouillées Ne placez aucun objet dans les ouvertures Ne l utilisez pas quand une des ouvertures est bloquée gardez les à l abri de la poussière de la charpie des...

Page 5: ...C Cet appareil doit être mis à la terre En cas de défaillance ou de panne éventuelles la mise a la terre fournit au courant un chemin de moindre résistance qui réduit le risque de choc électrique Cet appareil est pourvu d un cordon muni d un conducteur de terre et d une fiche avec broche de terre La fiche doit être branchée dans une prise appropriee correctement installée et mise à la terre confor...

Page 6: ...surethattheMainPowerSwitch 1 isinthe OFF position then plug the Power Cord 6 into a wall outlet 3 If you have an Air Scoop model re attach the Squeegee 9 and the Recovery Hose 8 If you have a non Air Scoop model re attach the recovery hose 4 Connect the other end of the Recovery Hose 8 to the Squeegee 9 or wand and wet pick up tool Accessory hoses wands and other attachments are available from you...

Page 7: ... machine with a damp cloth Check the Maintenance Schedule and perform any required maintenance before storage 7 Store the machine indoors in a clean dry place LUBRICATION Lubricatethecasterswivelsandthesqueegeeraise lowerpivotpointswithlight machine oil VACUUM MOTOR BRUSHES Have your Advance Dealer check the carbon motor brushes once a year or after 500 operating hours IMPORTANT Motordamageresulti...

Reviews: