FORM NO. 56041431 / GW 4512, GW 6016 -
6
AFTER USE - WET PICK UP
1
Step down on the Squeegee Raise/Lower Pedal
(4)
to raise the Squeegee
(Air Scoop model only). Turn the Main Power Switch
(1)
OFF and unplug
the Power Cord
(6).
2
Move the machine to a “DESIGNATED” waste water disposal site.
3
Remove the Drain Hose
(5)
from its hanger, direct the end of the hose to
a proper disposal area and remove the plug. On 100V model, remove the
Power Head
(2)
, lift out the Bucket
(14)
, empty and rinse with warm water.
4
Remove the Power Head
(2)
from the Recovery Tank / Chassis
(3)
and
rinse the tank with warm water.
NOTE:
Clean and inspect the Float
(B)
for debris or damage (Figure B).
5
Remove the Squeegee
(9)
or Wand and Recovery Hose
(8)
and rinse
them in warm water.
6
Dry out the Recovery Tank / Chassis
(3)
, Bucket
(14)
on 100V model,
before re-installing the Power Head
(2)
.
7
Wipe the machine with a damp cloth. Check the Maintenance Schedule
and perform any required maintenance before storage.
8
Store the machine indoors in a clean, dry place.
AFTER USE - DRY PICK UP
1
Turn the Main Power Switch
(1)
OFF and unplug the Power Cord
(6).
Remove the Power Head
(2)
from the Recovery Tank / Chassis
(3).
2
Remove the Dry Pick-up Filter and shake out, brush off and vacuum out
for normal up keep.
3
Reinstall the Dry Pick-up Filter on the Power Head
(2)
.
4
Empty the debris from the Recovery Tank / Chassis
(3)
, Bucket
(14)
on
100V model, rinse the tank (bucket) clean and dry it out.
5
Reinstall the Power Head
(2)
on the Recovery Tank / Chassis
(3)
and
Latch
(11)
into place.
6
Wipe the machine with a damp cloth. Check the Maintenance Schedule
and perform any required maintenance before storage.
7
Store the machine indoors in a clean, dry place.
LUBRICATION
Lubricate the caster swivels and the squeegee raise / lower pivot points with light
machine oil.
VACUUM MOTOR BRUSHES
Have your Advance Dealer check the carbon motor brushes once a year or after
500 operating hours.
IMPORTANT !
Motor damage resulting from failure to service the carbon brushes
is not covered under warranty. See the Limited Warranty State-
ment.
CAUTION !
Unplug the Power Cord
(6)
before performing any machine
maintenance.
MAINTENANCE SCHEDULE
Maintenance Item
Daily
Monthly
Yearly
Clean the Recovery Tank (Bucket)
X
Clean the Power Head
X
Clean the Float
X
Clean the Squeegee
X
Clean the Dry Pick-Up Filter
X
Inspect Tank and Hoses
X
**Inspect Power Cord
X
Lubrication
X
Inspect and Clean
Vac Motor Outlet Filter
X
*Check Vacuum Motor Brushes
X
*Have Advance check the carbon motor brushes once a year or after 500
operating hours.
** If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similarly qualified person in order to avoid a hazard.
TECHNICAL SPECIFICATIONS (as installed and tested on unit)
GW 4512 / GW 4512 AS
GW 4512 / GW 4512 AS
Model
GW 6016 / GW 6016 AS
GW 6016 / GW 6016 AS
GW 4512
56209801 / 56209806
56209803 / 56209809
Model Number
56209802 / 56209807
56209805 / 56209813
56210000
Voltage/frequency
V/Hz
120V / 50/60Hz
220-240V / 50/60Hz
100V / 50/60Hz
Rated Power
W
800
1,100
1,200
Protection Class (electrical)
Protection grade (mec, moist, dust)
N/A
IP 34
N/A
Sound Pressure Level (at operator’s ear)
dB(A)/20
µ
Pa
75
75
75
Vibration at the Hand Controls
m/s
2
<2.5m/s
2
<2.5m/s
2
<2.5m/s
2