background image

OPERATION

REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE

HIGH PRESSURE WASHER

1

Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make
sure hoses are in good condition and the spray nozzle(s) is tight.

REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGES.

2. If you choose to use the automatic pump-out feature, connect the dump hose to the brass hose fitting

on the back of the machine, and place the open end of the hose in a drain.  Make sure the drain hose
on the back of the vacuum tank is closed, and the lid is tight on the recovery tank. NOTE: never turn
ON the automatic pump-out switch unless you have removed the brass cap from the hose connector on
the rear of the machine. This pump will run continuously if it is turned on, and if the water can not be
pumped out (cap still screwed on) damage may occur to the pump.

If you choose not to use the auto pump-out option, just make sure the brass cap is on the hose
connector on the rear of the machine. CAUTION: do not turn the pump-out switch on if the cap is still
on the hose connector on the back of the machine.

3. If you choose to use the auto-fill feature, connect the fill-hose to the auto-fill valve (located over the

solution tank fill hole). Turn on the water source. NOTE: do not turn the water on full power. The water
flowing into the auto-fill system does not need a lot of pressure behind it. Allow the tank to fill with
solution. When you use the auto-fill system, the auto-fill valve will automatically turn on and turn off as
the tank empties and then fills. NOTE: If you are not going to use the auto-fill system,

just fill the

tank with water and cleaning chemical. Follow chemical directions regarding dilution and mixing. Do not
use harsh chemicals; they may damage seals in pumps and valves, and cause the pump to wear
prematurely.  NOTE: Never put water in the tank with a temerature exceeding 54 

°

C/130 

°

F.

4. Pre-spray the area to be cleaned with a pump-up sprayer. Follow chemical directions.

5. Plug in the power cord. Turn on the high pressure pump by placing the HIGH PRESSURE/HEAT selection

switch (2) in the UP position, to select the High Pressure Pump.  NOTE: The high pressure pump and
the heat can not operate at the same time.   NOTE: this switch is off when it is set to the middle
position and neither the high pressure pump nor the heater is selected.

6. The 85 bar pump is not self-priming; you will need to prime the high pressure pump using the ‘power

prime’ system: turn on both the pump and the vacuum, cover the hole in the hose barb with your
hand, then depress the Power Prime Pedal. This will pull trapped air out of the pump and into the
recovery tank

 

, priming the pump.  You will notice a ‘tone’ change in the pump (smoother, with less of a

rattle), and the water being pulled into the recovery tank will change from a white, full of air stream of

continue on next page

CAUTION:  IF FOAM OR WATER COMES OUT THE VACUUM EXHAUST,
 TURN THE MACHINE OFF IMMEDIATELY

CAUTION

:  Never leave the 85 bar pump running if you are not actively using it

Summary of Contents for HSC 585

Page 1: ...1 11600205211REVA INFORMATION OPERATING INSTRUCTIONS 10 22 2007 HSC 585 MULTI EXTRACTOR 220 240V EU CAUTION DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL 26022008...

Page 2: ...r Do not pull the machine by the cord do not use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away fr...

Page 3: ...any scheduled maintenance however the vacuum motors may require replacement brushes after 1000 1500 hours and the high pressure pump and unloader valve may require rebuild kits after 500 1000 hours re...

Page 4: ...WITCH 2 4 HEAT SELECTED LIGHT KNOW YOUR MACHINE HSC 585 MULTI Switches 85 Bar Quick Disconnect Hoses Vacuum Hose Connection Base Compartment Vac Tank Latch 7 Bar Quick Disconnect Solution Tank Wheel D...

Page 5: ...to fill with solution When you use the auto fill system the auto fill valve will automatically turn on and turn off as the tank empties and then fills NOTE If you are not going to use the auto fill s...

Page 6: ...working to fill and or empty your tanks 11 When the job is finished turn off the automatic pump out pump turn and turn off the water source if they were employed Use the vacuum hose to suck the remain...

Page 7: ...arb on the top left of the recovery tank Connect the other ends of both hoses to the cleaning tool 8 Turn on the 7 bar demand pump 4 NOTE the demand pump will not run until pressure is released 9 Spra...

Page 8: ...Turn on the water supply Do NOT turn the water on full pressure This system does not require a high presssure water source Just turn the water on 4 The float for the automatic fill will shut off the f...

Page 9: ...When there is water in the recovery tank it will automatically pump out After each job run clear water though the automatic pump out to wash out any chemical residue Remove and clean the stainless ste...

Page 10: ...23 2 3 4 5 6 7 8 9 10 12 14 17 13 15 20 37 25 23 32 28 18 30 20A 11 1 29 26 16 21 27 31 21A 22 34 24 19 HSC 585 Multi REV A 3 8 08...

Page 11: ...t 7 bar 19 1 600758519 Pump and motor complete 85 bar 20 1 600758520 Pump complete 85 bar no motor 20A 1 600758544 Pressure regulator unloader valve 21 1 600758541 Relay kit vacuum motor 21A 1 6007585...

Page 12: ...e small areas 35 to 172 bar 500 2500 psi Use it on floors or walls Lightweight but sturdy No wheels to restrict 360 travel Water temperature up to 110 C 230 F 600305899 60070045 60070043 STAINLESS STE...

Page 13: ...uum Rated Power Pump Suction Power Vacuum at Nozzle Heat Suction Width Weight Dimensions 3 stage 2950 W maximum Positive displacement 83 bar Demand 7 bar 372 W 30 4 KPA to 100 C 38 mm 89 5 KG 39 H x 2...

Reviews: