background image

water to a clear, solid stream. Priming may take 20 - 60 seconds, or even longer sometimes, and it will

require a full solution tank. When the pump is primed, let off the Power Prime Pedal, and turn off the
pump and the vacuum. Then press the Power Prime Pedal once again, for a moment, to release the line
pressure; you will hear a ‘swoosh’ of air as the back pressure in the lines is released. The pump will need
to be primed anytime air gets into it -- try not to let the pump run dry.  Proceed to the next step.

7. Add defoamer to the recovery tank.

8. Attach the solution spray hose to the solution quick disconnect.  Attach the vacuum hose to the hose

barb on the front of the recovery tank.  Pull the hoses out from the reel.  Attach the other ends of the
hoses to the cleaning tool.

9. If you choose to use the automatic pump-out feature, MAKE SURE THE CAP IS REMOVED FROM THE

HOSE CONNECTION ON THE BACK OF THE MACHINE BEFORE YOU TURN THE SWITCH ON. This
pump will run continuously once you turn it on, and if it tries to pump out water, but the cap is still on the
hose fitting, the pump may be damaged.

10. Turn on the vacuum (3) and turn on the dump pump (if you chose to use this feature) (5). Begin

spraying.  If you are not using the auto-fill or auto-dump features, turn off the pump and vacuum when
the solution tank gets low; fill the solution tank, and empty and clean the recovery tank. If you use the
auto-fill and/or auto-dump features, you will not need to stop working to fill and/or empty your tanks.

11. When the job is finished, turn off the automatic pump-out pump turn and turn off the water source, if

they were employed. Use the vacuum hose to suck the remaining solution from the holding tank into the
recovery tank.

13. Run a few gallons of clean water through the system. Completely empty the recovery tank by placing the

drain hose over a floor drain, toilet, or tub, and removing the cap. You can clean the tank at this time with
clean water. When the tank is empty, cap the drain hose and place it back in the hook and loop holder.
Disconnect the hoses from the cleaning tool, and reel them up onto the hose spool.

14. Unplug the power cord.  Clean the machine and the tool.

LOW PRESSURE AND HEAT

1 Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Make

sure hoses are in good condition and the spray nozzle(s) is tight.

REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON THE FOLLOWING PAGE

2. If you choose to use the automatic pump-out feature, connect the dump hose to brass hose fitting on

the back of the machine, and place the open end of the hose in a drain. NOTE: NEVER TURN ON THE
PUMP OUT PUMP UNTIL YOU HAVE REMOVED THE CAP FROM THE HOSE CONNECTOR ON THE REAR
OF THE MACHINE. Make sure the drain hose on the back of the vacuum tank is closed and the lid is tight
on the recovery tank. If you are not going to use the auto pump-out option, just make sure the brass
cap is on the hose connector on the rear of the machine.

HIGH PRESSURE continued

continue on next page

CAUTION:  if foam or water comes out the vacuum exhaust, turn
the machine off immediately

Summary of Contents for HSC 585

Page 1: ...1 11600205211REVA INFORMATION OPERATING INSTRUCTIONS 10 22 2007 HSC 585 MULTI EXTRACTOR 220 240V EU CAUTION DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL 26022008...

Page 2: ...r Do not pull the machine by the cord do not use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away fr...

Page 3: ...any scheduled maintenance however the vacuum motors may require replacement brushes after 1000 1500 hours and the high pressure pump and unloader valve may require rebuild kits after 500 1000 hours re...

Page 4: ...WITCH 2 4 HEAT SELECTED LIGHT KNOW YOUR MACHINE HSC 585 MULTI Switches 85 Bar Quick Disconnect Hoses Vacuum Hose Connection Base Compartment Vac Tank Latch 7 Bar Quick Disconnect Solution Tank Wheel D...

Page 5: ...to fill with solution When you use the auto fill system the auto fill valve will automatically turn on and turn off as the tank empties and then fills NOTE If you are not going to use the auto fill s...

Page 6: ...working to fill and or empty your tanks 11 When the job is finished turn off the automatic pump out pump turn and turn off the water source if they were employed Use the vacuum hose to suck the remain...

Page 7: ...arb on the top left of the recovery tank Connect the other ends of both hoses to the cleaning tool 8 Turn on the 7 bar demand pump 4 NOTE the demand pump will not run until pressure is released 9 Spra...

Page 8: ...Turn on the water supply Do NOT turn the water on full pressure This system does not require a high presssure water source Just turn the water on 4 The float for the automatic fill will shut off the f...

Page 9: ...When there is water in the recovery tank it will automatically pump out After each job run clear water though the automatic pump out to wash out any chemical residue Remove and clean the stainless ste...

Page 10: ...23 2 3 4 5 6 7 8 9 10 12 14 17 13 15 20 37 25 23 32 28 18 30 20A 11 1 29 26 16 21 27 31 21A 22 34 24 19 HSC 585 Multi REV A 3 8 08...

Page 11: ...t 7 bar 19 1 600758519 Pump and motor complete 85 bar 20 1 600758520 Pump complete 85 bar no motor 20A 1 600758544 Pressure regulator unloader valve 21 1 600758541 Relay kit vacuum motor 21A 1 6007585...

Page 12: ...e small areas 35 to 172 bar 500 2500 psi Use it on floors or walls Lightweight but sturdy No wheels to restrict 360 travel Water temperature up to 110 C 230 F 600305899 60070045 60070043 STAINLESS STE...

Page 13: ...uum Rated Power Pump Suction Power Vacuum at Nozzle Heat Suction Width Weight Dimensions 3 stage 2950 W maximum Positive displacement 83 bar Demand 7 bar 372 W 30 4 KPA to 100 C 38 mm 89 5 KG 39 H x 2...