FORM NO. 56043055 / HR 2800, HR 2800C / BR 700, BR 700C
- 47
ELECTRICAL SYSTEM
RECALL OF STORED ERROR (FAULT) CODES:
Whenever an electrical system fault is detected by the main control unit, one or more error codes are displayed and stored by the control
unit. If it is desired, the error code (if any) from the previous operation of the machine can be recalled for troubleshooting purposes. To
recall the last stored error codes perform the following steps:
1
Turn the master on/off key switch to the off position.
2
Press and hold the heavy scrub switch.
3
While holding the heavy scrub switch turn the master on/off key switch to the on position.
4
Continue to hold the heavy scrub switch until the hourmeter/status display shows “Error”.
5
Release the heavy scrub switch.
6
If there were previously no error codes stored, the display will now show “nonE”. Go to step 12.
7
If error codes were stored, the display will now show the stored code(s) and the heavy scrub indicator will now be green.
8
To clear the stored codes press and release the heavy scrub switch.
9
The hourmeter/status display will now show “ErASE” and the scrub off indicator will be red.
10
To clear the stored codes, press and release the heavy scrub switch one more time. To return to the error code display without
clearing the codes press the scrub off switch.
11
If the heavy scrub switch was pressed the error codes will have been cleared and the display will show “nonE”.
12
To exit the error code recall mode, turn the master on/off key switch to the off position.
ENABLING OR DISABLING THE VACUUM AUTOMATIC SHUTOFF OPTION:
The HR 2800 / BR 700 is equipped with a feature that will automatically shut off the vacuum and display “FULL” on the hourmeter/status
display if the recovery tank becomes filled. If problems are encountered with the vacuum automatic shutoff feature, such as the vacuum
shutting off even if the recovery tank is not full, this feature can be disabled. To enable or disable this feature perform the following steps:
1
Turn the master on/off key switch to the off position.
2
Press and hold the vacuum switch.
3
While holding the vacuum switch turn the master on/off key switch to the on position.
4
Continue to hold the vacuum switch until the hourmeter/status display shows “OFF” or “on” and the vacuum indicator is green.
5
Release the vacuum switch.
6
Pressing and releasing the vacuum switch will now select between “on” or “OFF”. On means that the vacuum automatic shutoff
feature is enabled, off means that the feature is disabled.
7
To save the new setting, turn the master on/off key switch to the off position.
8
The new setting will be saved and will remain in effect until it is changed again.
ENABLING OR DISABLING SOLUTION FLOW WHILE IN REVERSE:
Normally while scrubbing, the solution flow is stopped while in reverse to prevent flooding of the floor due to the fact that the squeegee
raises when backing up. If it is desired to allow solution flow while in reverse this feature can be enabled. To enable or disable this feature,
perform the following steps:
1
Turn the master on/off key switch to the off position.
2
Press and hold the solution switch.
3
While holding the solution switch turn the master on/off key switch to the on position.
4
Continue to hold the solution switch until the hourmeter/status display shows “OFF” or “on” and the solution indicator is green.
5
Release the solution switch.
6
Pressing and releasing the solution switch will now select between “on” or “OFF”. On means that the solution flow will be on while
in reverse, off means that the solution flow will be stopped while in reverse.
7
To save the new setting, turn the master on/off key switch to the off position.
8
The new setting will be saved and will remain in effect until it is changed again.
MAIN CONTROL BOARD SPECIAL PROGRAM OPTIONS FOR MACHINES BEFORE
SERIAL NUMBER 1362502 (CONTINUED)
revised 2/05