12
english
IVB 3-H
IVB 5-H
IVB 7-H
7.2.3 Replacing filter element
„H“ (IVB 3-H)
3. Open the retaining clamps and
remove the upper section of the
cleaner from the dirt tank. Lay
the upper section of the cleaner
down with the filter element fac-
ing upwards.
4. Using the enclosed tool (2), turn
the filter holder (1) anticlockwise
and remove it.
5. Place the protective filter bag
over the filter element (3).
6. Carefully remove the filter ele-
ment and close the protective
filter bag with a knot.
7. Clean the filter seal (4). Check it
for damage and replace it if nec-
essary.
8. Check the antistatic clamp (5)
for damage and have it replaced
by Nilfisk-Advance Service if
necessary.
9. Fit a new filter element.
10. Check that the float (6) works
properly. When the filter holder
is turned, the float inside must
move about easily.
11. Using the enclosed tool, attach
the filter holder and turn it clock-
wise to lock it.
12. Dispose of the used filter ele-
ment in accordance with legal
regulations.
7.2.4 Replacing filter element
„H“ (IVB 5-H/7-H)
During the following
work, ensure that dust
is not unnecessarily
spread around. Wear a
cleaner down with the filter ele-
ment facing upwards. Do not
place the upper section of the
cleaner on the guard (1) and do
not damage the filter element.
2. Unscrew the screw (2), open the
bar handle and remove it.
3. Remove the filter holder (3).
4. Place the protective filter bag
over the filter element.
5. Carefully remove the filter ele-
ment and close the protective
filter bag with a knot.
6. Clean the filter seal (4). Check it
for damage and replace it if nec-
essary.
7. Check the antistatic clamp (5)
for damage and have it replaced
by Nilfisk-Advance Service if
necessary.
During the following work,
ensure that dust is not
unnecessarily spread
around. Wear a P2
breathing mask.
P2 breathing mask.
Never use the vacuum cleaner with-
out a filter.
1. Remove the upper section
of cleaner from the dirt tank.
Lay the upper section of the
4
1
3
2
Never use the vacuum cleaner with-
out a filter.
1. Clean the filter element (see
4.5).
2. Switch off the vacuum clean-
er and wait approx. 5 minutes
so that the dust can settle in
the tank.
1
2
3
6
5
4