Solution System 101
Service Manual – Scrubtec R 253 - RA40
Troubleshooting (Continues)
Trouble
Possible Causes
Remedy
The Chemical Mixing System detergent is
not reaching the brush, or is not arriving
in sufficient quantity
The detergent flow percentage is too low
Check/change the percentage as
shown in the User Manual
The hydraulic circuit upstream of the detergent pump is
not triggered
Check if the hose is filled and, if
necessary, perform one or more
draining cycles
The pump (M1) is broken or there is an open in the
electrical connection
Replace the pump/repair the
electrical connection
There is foreign material/debris in the detergent tank
clogging the output hole
Clean the tank
There is debris in the detergent hoses clogging the
detergent flow
Clean the hoses
Function electronic board (EB1) faulty
Replace
Display electronic board (EB2) faulty
Replace
Dashboard instrument electronic board (EB4) faulty
Replace
The Chemical Mixing System detergent
is reaching the brush even with the
machine off
The pump (M1) is broken
Replace
The one-way valve is broken
Replace
Water is entering the Chemical Mixing
System tank
The one-way valve is broken
Replace
The Chemical Mixing System will not
activate
Dashboard instrument electronic board (EB4) faulty
Replace
The function electronic board (EB1) has not been set for
operation with the Chemical Mixing System
If present, remove the jumper
(J6) (Figure 9) on the rear of the
function electronic board
Figure 9
https://harrissupplyind.com - To Order Parts Call 608-268-8080