Recovery System
74
Service Manual – Scrubtec R 253 - RA40
Removal and Installation
Vacuum System Motor Unit Disassembly/Assembly
Disassembly
1 Remove the operator key
2 Disconnect the red battery connector
3 If present, drain the recovery tank, then lift it
4 Disconnect the connector (A) (Figure 6) and remove the fastening clamp
5 Unscrew the 3 screws (B) and remove the vacuum system motor unit (C)
Figure 6
B
B
C
B
A
Assembly
6 Assemble the components in the reverse order of disassembly
https://harrissupplyind.com - To Order Parts Call 608-268-8080