Solution System
93
Service Manual – Scrubtec R 253 - RA40
Water Level Sensor Operation
The water level sensor (SW1) is positioned about half the height of the solution tank so as to provide the in-
formation to the electronic system on the level of water present in the tank (more than half, less than half)
Through this information the times of opening of the solenoid valve (EV1) and the detergent pump (M4) are
adjusted to maintain this flow more constant
(Figure 1)
The water level sensor is capacitive with NPN output (output 0 Volt with water, floating without water).
Full
½
Empty
Solution tank
With sensor
Without sensor
Solution flow to the brush (Litre/min)
Figura 1
J5.1
J5.2
J5.3
FUNCTION ELECTRONIC BOARD (EB1)
WATER LEVEL SENSOR (SW1)
24V
(B+)
0V
(B-)
Power Supply
Input
5V
Figura 2
https://harrissupplyind.com - To Order Parts Call 608-268-8080