Solution System
97
Service Manual – Scrubtec R 253 - RA40
Maintenance and Adjustments
Cleaning the Solution Tank and Filter
1
Drive the machine on a level floor.
2 Ensure that the machine is off and the operator
key has been removed
3 Close the solution tank valve
4 Remove the transparent cover (A, Figure 7),
retrieve the gasket (B), then remove the filter
strainer (C)
5
Wash and rinse them with water, then refit
them carefully onto the filter support (D).
6 Open the solution tank valve
A
C
B
D
Figure 7