Hydraulic system data
Values
Maximum drive system pressure
3,626 psi (250 Bar)
Suction fan system maximum pressure
3,046 psi (210 Bar)
Maximum accessory system pressure
3,046/1,885 psi (210/130 Bar)
Hydraulic system oil viscosity [at ambient temperatures above +50°F (+10°C)] (*)
46 cSt
Hydraulic system oil type
Brake
fl
uid type
If the machine is to be used at ambient temperatures below +50°F (+10°C), the oil should be replaced with equivalent oil
(*)
having a viscosity of 32 cSt. For temperatures below +32°F (0°C), use oil with lower viscosity.
See the hydraulic system oil technical data and reference data tables below.
(**)
See the brake
fl
uid technical data and reference data tables below.
(***)
AGIP ARNICA SPECIFICATIONS
46
32
Approvals and speci
fi
cations
Viscosity at +104°F (+40°C)
mm
2
/s
45
32
Viscosity at +212°F (+100°C)
mm
2
/s
7.97
6.40
Viscosity index
/
150
157
Flash point COC
°F (°C)
419 (215)
395.6 (202)
Pour point
°F (°C)
-32.8 (-36) -32.8 (-36)
Density at +59°F (+15°C)
kg/l
0.87
0.865
DOT4 SPECIFICATIONS
Approvals and speci
fi
cations
Viscosity at -40°F (-40°C)
mm
2
/s
1,300
Viscosity at +212°F (+100°C)
mm
2
/s
2.2
Dry boiling point
°F (°C)
509 (265)
Wet boiling point
°F (°C)
338 (170)
Density at +59°F (+15°C)
kg/l
1.07
Color
/
Yellow
Climate control system data
Values
Gas type
Gas quantity
1.76 lb (0.8 kg)
Camera kit description (optional) (*)
Values
Make
Continental VDO -
Type
LCD 5” color monitor
Infrared color camera
For other data/values of the optional equipment, see the relevant Manuals.
(*)