14
Min. 3 timer
Wear gloves !
•
Turn of the water supply
to the unit
•
Set the unit in rinsing
position
•
Dismount the outlet hose
•
Screw of the drain plug in
the top of the unit. Screw
it in the bottom.
•
Fill in 0.5 dl descaling
fluid. Use the enclosed
measuring cup.
•
Leave the descaling fluid
in the unit for min. 15 min.
•
Move the drain plug
to the top of the unit.
Always remember to
wear gloves.
•
Connect the outlet hose
and turn on the water.
Eng
lis
h (
EN
)
6.
Operation procedures
6.1.
Before Operation
Before putting the S105 into operation please follow
the instructions below:
•
Connect the unit to the water supply using the
enclosed inlet hose.
•
Be wware the the filter is conncted between hose
and unit.
•
Connect the outlet hose and the handle.
•
The correct chemical limiting nozzle is selected
from the below table and connected to the hose
coupling nipple of the chemical non return valve.
•
The chemical hose is led through the hole of the
unit and above the chemical limiting nozzle and
the hose coupling nipple of the chemical non
return valve.
6.2. Deliming
Mounting of chemical limiting nozzle