Control System
23
Service Manual – SC2000
Function Electronic Board (EB1) Alarm Codes (Continues)
Function electronic board alarms
Alarm on function electronic board - FLASHING RED LED
Alarm code
--------------------------
Description
No.
flashes on
electronic
board
Meaning
Condition
Effect
Service Suggestions
F2
-----------------------
BRUSH MOTOR
OVERLOAD
2
BRUSH motor
amperometric
protection.
The voltage drop
measured on fuse F1 is
greater than the value of
the parameter (see page
29) VS1
Brush
electromagnetic
switch output
block.
Check the amperage of the brush motor.
It should remain below the value set in the
parameter “VS1” during operation.
F3
-----------------------
VACUUM
MOTOR
OVERLOAD
3
VACUUM
SYSTEM
amperometric
protection.
The amperage of the
vacuum system motor is
greater than 30A for over
10 seconds.
Vacuum system
block.
1. Check for any debris in the vacuum
system motor.
2. Check that the motor rotor turns freely.
3. Replace the vacuum system motor if
necessary.
F4
-----------------------
DECK
ACTUATOR
FAILURE
4
DECK
ACTUATOR
overcurrent.
Current greater than 4A
detected for more than 1
second.
Brush function
block.
1. Check that there is no friction on
the brush deck linkage; lubricate if
necessary.
2. Check that the actuator and deck
travel is not blocked by mechanical
obstructions.
3. If the problem persists, replace the
actuator.
F5
-----------------------
SQUEEGEE
ACTUATOR
FAILURE
5
SQUEEGEE
ACTUATOR
overcurrent.
Current greater than 4A
detected for more than 1
second.
Vacuum function
block.
1. Check that there is no friction on
the brush deck linkage; lubricate if
necessary.
2. Check that the actuator and deck
travel is not blocked by mechanical
obstructions.
3. If the problem persists, replace the
actuator.
F6
-----------------------
HARDWARE
FAILURE
5
Short circuit on
the vacuum or
brush motor drive
MOSFET.
MOSFET short circuit.
Function block.
1. Check that there are no short circuits in
the motor wiring.
2. Replace the electronic board.
F7
-----------------------
OVERHEATING
7
Motor drive
section thermal
cut-out.
The heatsink on the
electronic board has
reached a temperature of
194 °F (90 °C).
Function block.
Check the vacuum system and brush
motor amperage; also check that the
openings of the electrical compartment are
not blocked.
F8
-----------------------
BRUSH MOTOR
FAILURE
8
Brush motor
output short
circuit.
I > 150A for 20µsec.
Function block.
Check for short circuits in the wiring or
motor.
F9
-----------------------
VACUUM
MOTOR
FAILURE
9
Vacuum system
motor output
overcurrent.
I > 150A for 20µsec.
Function block.
Check for short circuits in the wiring or
motor.