Control System
28
Service Manual – SC2000
Machine Settings Screen
The machine settings screen (Figure 9) functions allow you to customise some parameters described in the
following table of modifiable parameters.
1. Press the vacuum system button
to increase the value of the current parameter.
2. Press the brush engagement/disengagement button
to decrease the value of the current
parameter.
3. To move to the next parameter press the One-Touch button
, or hold it for 1 second to return to
the main screen (Figure 6).
Figure 9
MODIFIABLE PARAMETERS
Code
Description
Min. Value
Factory Setting
Max. Value
CHM1
Detergent concentration level 1
1:500 (0.25 %)
1:500 (0.25 %)
1:33 (3 %)
CHM2
Detergent concentration level 2
1:500 (0.25 %)
1:125 (0.80 %)
1:33 (3 %)
P1/P3
Level 1 solution flow rate in relation to level 3
(see “System for Flow Rate Regulation as Function of Speed”
paragraph)
0 %
25 %
100 %
P2/P3
Level 2 solution flow rate in relation to level 3
(see “System for Flow Rate Regulation as Function of Speed”
paragraph)
0 %
50 %
100 %
P3
Level 3 solution flow rate
1.0 cl/m
3.0 cl/m
5.0 cl/m
P4
Level 4 enabling (2.8 l/min regardless of speed)
OFF
OFF
ON
SPT
EcoFlex function timer
0 (disabled)
60 sec.
300 sec.
XPRES
Brush deck extra pressure enabling
OFF
ON
ON
FVMAX
Maximum forward speed
10 %
100 %
100 %
RVMAX
Maximum reverse speed
10 %
30 %
50 %
WSMIN
Minimum working speed
10 %
25 %
100 %
WSMAX
Maximum working speed
10 %
100 %
100 %
BRK
Electromagnetic brake activation delay
0 sec.
3 sec.
5 sec.
BAT
Installed battery type
0
1
5
TOFF
Automatic shut-off time
0 (disabled)
300 sec.
600 sec.
BRGH
Display contrast
5
20
50
VRID
Vacuum power in silent mode
1
1
5
RPM
(*)
Reduced brush rpm activation threshold
5
9
20
RESET
Restore factory settings for all parameters
OFF
OFF
ON
(*) Increase the value of this parameter to reduce the brush motor speed in a wider range of applications and