Electrical System
45
Service Manual – SC2000
Maintenance and Adjustments
Setting the Installed Battery Type
Set the machine and the on-board battery charger (where fitted) on the basis of the type of battery to be in
-
stalled by modifying the BAT parameter as shown.
1. Insert the super user key (yellow) in place of the operator key (grey) to access the main screen (Figure 4)
of the multifunction display.
2. Press the One-Touch button
to continue to the machine settings screen (Figure 5).
Figure 4
Figure 5
3. Press the One-Touch button
until you reach the BAT parameter.
MODIFIABLE PARAMETERS
Code
Description
Min. Value
Factory Setting
Max. Value
BAT
Installed battery type
0
1
5
4. Press the vacuum system button
or brush engagement/disengagement button
to modify the
value of the BAT parameter as per the following table:
Code BAT
Value
Installed battery type
0
WET
Wet cell batteries
1
GEL / AGM
Generic GEL or AGM batteries
2
GEL EXIDE
EXIDE
®
/SONNENSHINE brand GEL batteries
3
GEL OPTIMA
OPTIMA™ brand GEL batteries
4
GEL DISCOVER
DISCOVER
®
brand GEL batteries
5
GEL FULLRIVER
FULLRIVER
®
brand GEL batteries
5. Press the One-Touch button
for more than 1 second to confirm the chosen parameter and return
to the main screen (Figure 4).