Electrical System
48
Service Manual – SC2000
Battery Charge State Display
(Significant levels for machine operation)
INDICATION
TRANSITION THRESHOLD (VOLT)
CONSEQUENCE
WET
GEL
1
22V
22.2V
Little remaining run time, no block.
2
20.4V
21.6V
Brush OFF
3
19.4V
20.6V
Vacuum system OFF
4
18.4V
19.6V
Drive system OFF
Checking/Replacing Fuses
1.
Drive the machine on a level floor and remove the operator key.
2. Disconnect the red battery connector by pressing the emergency push-button.
3. Lift the recovery tank.
4. Remove the 3 screws and remove the upper cover.
5. Remove the 2 screws and remove the electronic board front cover.
6. Check/replace the following fuses (Figure 7):
◦
(F1) 100A midi fuse - Function electronic board (A).
◦
(F2) 3A blade fuse - Signal circuits (B).
7. Place the function electronic board assembly in its housing, tighten the mounting screws and install the
electronic component compartment cover.
Figure 7
B
B
A
A