Solution System
74
Service Manual – SC2000
Solution System
Functional Description
The solution system supplies water and detergent to
the brush when cleaning the floor. The solution tank is
also the main machine body. There is a manual valve
on the left side of the tank, just under the rear wheel,
to close the water supply whenever maintenance must
be performed on the machine. The solution flows from
the tank to the valve, through the filter and solenoid
valve (EV1) and then to the brush deck.
The detergent pump (M4), present only on EcoFlex™
systems, controls the flow of detergent from the Eco
-
Flex™ tank which is then transported to the flow
in the main tube just before the solution enters the
brush deck.
The EcoFlex™ system can be selected with the spe
-
cific lever under the steering wheel.
The quantity of detergent is defined by the operator
via the buttons on the dashboard instrument elec
-
tronic board (EB4).
Solution flow levels 1, 2 and 3 regulate the flow of so
-
lution on the basis of the machine speed so as to keep
the quantity of solution dispensed per square metre of
floor treated constant (for further details and modifi
-
cations, see the corresponding paragraph in the chap
-
ter Control System).
Located centrally, below the solution tank, there is
also a hole for draining any liquid in the battery com-
partment.
The solution flow is regulated by various timed ON /
OFF cycles, according to:
• Water flow rate adjustment (0 - 4)
• Solution tank level
Both the solenoid valve and detergent pump (when
the EcoFlex™ system is enabled) follow the same tim
-
ings.
The solenoid valve and detergent pump operate only
with the following inputs/conditions:
• Driver’s seat microswitch closed
• Brush function on
• Forward pedal pressed
• Battery level not critical, display icon without
segments and flashing outline.
Wiring Diagram
OUT
-
+
J8.2
J8.1
J8.7
B+
B -
Electronic board power
Electronic board power supply -
J5.1
J5.2
J5.3
Power supply for water level
Water level sensor return
Power supply for water level sensor -
Detergent pump power supply -
Solenoid valve power supply -
Detergent pump power
FUNCTION
ELECTRONIC
BOARD (EB1)
SOLENOID VALVE
(EV1)
ECOFLEX™ PUMP
(M4)
SOLUTION LEVEL
SENSOR (SW1)
J8.6
Solenoid valve power
Figure 1