BATTERY CHARGE LEVEL
The battery charge level can be viewed on the battery icon
LEDs (5).
The battery charge percentage depends on the number of LEDs
lit, as shown in the figure 5.
When the first left LED flashes (15 %), the machine will only run
for a few more minutes (this will depend on the characteristics of
the work to perform).
STOPPING THE MACHINE
1. Turn off the machine by pressing the switch (2).
2.
Press the park pedal (10) to lift the brush/squeegee unit.
NOTE
If the machine is on but not working (without the
operator’s hands on the grip handles), it automatically
turns off after 2 minutes.
TANK EMPTYING
An automatic float shut-off system turns off the vacuum system
when the recovery tank is full.
The vacuum system deactivation is signalled by a sudden
increase in the vacuum motor noise, and the floor is not dried.
When the recovery tank is full, empty it according to the
following procedure.
Recovery tank emptying
1.
Turn the machine off and press the park pedal.
2. Drive the machine to the appointed disposal area.
3.
Turn and use the handle (A, Fig. 6) to lift the tanks
container (B) from the machine.
4.
Remove the cover (C) and empty the recovery tank; rinse
the tank with clean water at the end of the work.
Solution tank emptying
5. Perform steps 1 to 4.
6.
Remove the plug (14) and empty the solution tank. Then,
rinse the tank with clean water.
7.
Reinstall the tanks container (13) on the machine body
(16), rotate the handle (A) to the horizontal position and
reposition the tank cover (C).
MACHINE TRANSPORT/PARKING
1.
Stop and turn off the machine, then press the park pedal
(10).
2. While holding the machine in this position, drive it to the
appointed parking area.
3. If necessary, in order to manually lift the machine, bend the
handlebar (24) and grip the handle (25), then transport the
machine to the area where it is to be parked.
15% 30% 45% 60% 80% 100%
Figure 5
P100936
A
B
C
Figure 6
P100937