Solution System - Cable Version
86
Service Manual – SC450
Solution System - Cable Version
Functional Description
The solution system supplies the detergent to the
brushes when cleaning the floor. The solution tank is
also the main machine body The detergent quantity
is adjusted by the operator with the lever under the
solution tank, on the left rear side. The solution flows
from the tank to the tap, through the filter and sole
-
noid valve (EV1) and then to the brush deck
The solenoid valve (EV1) is supplied by the brush
motor relay (ES) when the switches (SW1) and (SW3
with SW4) are closed. The solution flow is regulated
by the manual solution flow control lever.
Wiring Diagram
BRUSH MOTOR RELAY (ES1)
SOLENOID VALVE (EV1)
MAINS FILTER (FL1)
MAINS PLUG (PL)
BRUSH SWITCH (SW1)
BRUSH ACTIVATION
PUSH-BUTTONS (SW3) (SW4)
P200033C