34
04 - Control System
Panel Test
The Panel Test screen provides a means to
verify the functionality of all of the control
panel switches, LEDs, and display pixels
The display shows a graphical representation
of all of the control panel switches When you
depress a switch
(A)
, its representation on
the screen highlights
(B)
to show the press
was detected
Pressing the Down Arrow
(C)
turns on all
of the panel LEDs to verify that they are
functional
Pressing the Up Arrow
(D)
will turn on
(scroll) through all pixels on the display
screen to detect if any pixels are dropping
out
The Left Arrow
(E)
returns to the previous
menu, and the Information button
(F)
exits
the menu system
Options Menu
The Options Menu provides for making machine settings specific for the uses and needs of the operator. This
menu is also available to the Supervisor, but not to the operator
Language:
This sets the interface language For the machine. The available languages are: Español,
Français, Deutsch, English, Italiano, and Português
Floor:
This sets the floor type for either standard or smooth.
Scrub Startup:
This sets the scrub mode default at startup The choices are Light, Heavy, Extreme, and
Last (Last means that whichever mode was selected during the previous session will remain for the next
session )
Scrub Max:
This sets the maximum permitted scrub level that the operator can select, and locks out any
levels above that The choices are Light, Heavy, and Extreme
Solution:
This sets the mode for solution rate The choices are Proportional, Fixed, and UK
Solution In Rev:
This sets whether solution will flow when the machine is in reverse.
Lock Detergent:
This sets whether the operator can adjust the detergent ratio
Headlight:
This sets whether the optional headlights are automatically turned on at startup
Neutral Delay (s):
This sets how long the brushes remain active (in seconds) when the machine is
stationary The minimum is 1/2 second, the maximum is 5 seconds, and the increment is every 1/2 second
Vac Off Delay (s):
This sets the length of time (in seconds) that the vacuum motor will continue to run after
the squeegee is lifted (to clear the hose of remaining water) The minimum is 10 seconds, the maximum is 20
seconds, and the increment is every 1 second
Burst Of Power (s):
This sets the length of time (in seconds) Burst of Power remains active after pulling
the BoP paddle The minimum is 60 seconds, the maximum is 300 seconds (5 minutes), and the increment is
every 60 seconds (1 minute)
B
A
C
D
E
F