04 - Control System
Fwd Speed Max (%):
This sets the maximum speed (percent of maximum) the operator can propel the
machine forward The minimum is 50%, the maximum is 100%, and the increment is every 10%
Lock Speed Limit:
This sets whether the operator can use the “set max speed” feature.
Inactivity Time (min):
This sets the length of time (in minutes) before the machine powers down after
inactivity The minimum is 1 minute, the maximum is 30 minutes, and the increment is every minute
Impact Detect:
This sets how the machine handles impact detection The choices are Off, record to log, and
lockout the machine
Impact Level:
This sets the threshold for impact detection The choices are high and low
Configuration Menu
The configuration menu provides technician-only access to configure the machine based on which options
are installed. If you install an option to a customer’s machine, you will need to configure the controller to
specify that the option is installed, or the option may not function Additional information is contained in the
instruction sheets that accompany the option kits
Brand:
This sets the branding of the machine (Nilfisk or Advance). This should never be changed unless you
are replacing the main controller
Deck:
This sets the deck type installed on the machine. The options are (Advance/Nilfisk) 34D/860D,
40D/1050D, and 36C/910C
Side Broom:
This sets whether the optional side broom is installed This option is available only for
36C/910C machines If the side broom kit also includes Dust Guard, you will also need to set the option
pump type too
Ecoflex:
This sets whether the EcoFlex detergent pump system is installed
Opt Pump:
This sets whether the option pump is installed, and which of the two choices are used The
choices are None, Spray Wash, and Dust Guard Note that the same machine cannot have both the spray
hose and Dust Guard options installed
Battery:
This sets the battery type for the purpose of battery voltage monitoring The choices are Wet and
AGM The battery types will have slightly different voltage levels during their discharge cycles
Charger:
This sets whether the onboard battery charger is installed Note that if you set this to Yes, but no
charger is installed, the machine will be disabled Likewise, setting this to No when a charger is installed,
can result in damage to the charger Refer to the Troubleshooting section,
Vacuum:
This sets whether there is 1 vacuum motor or 2 vacuum motors
Backup Alarm:
This sets whether the backup alarm is installed
Headlight:
This sets whether the headlights are installed
TrackClean:
This sets whether the TrackClean module is installed