56041481
USE
In order to get an efficient cleaning function the panel
filter must always be clean.
Press the filter-shaker button, even if the machine is
working.
This operation must be repeated every 10 to 15
minutes, depending on the kind of rubbish to be swept;
before emptying the dirt container and, in any case, at
the end of the work.
During the operation of the filter-shaker the suction
fan will continue to run (no automatic stop will occur).
If you want to stop the suction fan during the filter
shaker operation - two possibilities exist:
1st
- to stop the fan by pressing the dedicated ON/OFF
button.
2nd
- to wait for the functions automatic power off
(after the release of the accelerator pedal)
To restart the suction fan either press the ON/OFF
button or use the accelerator pedal.
As an alternative - in order to make easier the
operator’s job - the automatic filter sheaking will occur,
every five minutes.
To collect light and bulky waste materials lift the front
flap using the left pedal (do not press the pedal down
for a long time, not to reduce the suction capability of
the machine).
The machine get an automatic breaking function when
the accelerator pedal is released; when necessary the
service brake can also be used (see the figure).
When driving reverse an intermittent acoustic signal
will be heared and all the functions will remain
enabled.
In the figure the functions of the command lever are
shown:
1
- forward speed
2
- reverse speed
3
- horn
4
- front light On/Off.
The machine is equipped with an emergency stop
button; by pressing this button (red light On) a sudden
stop of the machine will occur and all functions will
turn Off, the gasoline engine too.
To restart the machine turn the red button clockwise
(according to the arrow shown on the button itself).
To restart the normal operation re-select one of the
two working programs
P1
or
P2
and restart the
gasoline engine.
1
4
2
3
11