21
EN
INSTALLATION, USE AND MAINTENANCE MANUAL
• Dust container emptying
: This procedure is used to modify the parameter that controls alarm
operation, set by default at 10 hours on models 0 and 0. Enter the USER MENU by pressing the SET
button when the display shows the STANDBY message.
Scroll through the USER MENU with the UP and DOWN keys until you reach the EMPTY CONTAINER
submenu. Press the SET button and then use the UP and DOWN keys to enter the desired value.
To memorize the new value entered, keep the SET button pressed down for a few seconds until the
MEMORIZED message appears.
To leave this display press the RESET button.
• Self-cleaning function
: This procedure is used to modify the parameter that controls the self-cleaning
operation, set by default at 90 minutes. Enter the USER MENU by pressing the SET button when the
display shows the STANDBY message.
Scroll through the USER MENU with the UP and DOWN keys until you reach the SELF-CLEANING
submenu. Press the SET button and then use the UP and DOWN keys to enter the desired value.
To memorize the new value entered, keep the SET button pressed down for a few seconds until the
MEMORIZED message appears.
To leave this display press the RESET button.
• Continuous operation
: This procedure is used to modify the parameter that controls alarm operation,
set by default at minutes.
Enter the USER MENU by pressing the SET button when the display shows the STANDBY message.
Scroll through the USER MENU with the UP and DOWN keys until you reach the CONTINUOUS
OPERATION submenu. Press the SET button and then use the UP and DOWN keys to enter the desired
value.
To memorize the new value entered, keep the SET button pressed down for a few seconds until the
MEMORIZED message appears.
To leave this display press the RESET button.
6.3 Display of personalized maintenance parameters
With the procedures described here, users can view the most recent maintenance parameters
programmed, with a series of simple operations on the user interface.
Enter the USER MENU by pressing the SET button when the display shows the STANDBY message.
Scroll through the USER MENU with the UP and DOWN keys until you reach the desired submenu. The
most recent value entered will be displayed.
To leave this display press the RESET button until the STANDBY message reappears