VHB436N
7
C504
US
Technical data
Parameter
Units
VHB436Nx
2 Battery (Standard)
3 Battery (Optionals)
Voltage
Volts
36
Power rating
kW
2.4
Current Draw, rated
Amps
14.5
Waterlift, max
Inches H2O
51.2
Maximum air flow rate without hose
and reductions
cfm
250
Maximum air flow rate (3 m Ø 50 mm
hose)
cfm
170
Sound pressure level (*)
dB(A)
71
Vibration, ah (**)
m/s
2
≤2.5
Insulation Class
Class
III
Tank Capacity
Gallons/liters
13 / 50
Machine Inlet
Inches
2.75
Filter Area, main
Sq. ft
21
Filter Area, optional HEPA
Sq. ft
37.7
Absolute filter efficiency according to
MPPS method
%
99.995
@ 0.18 micron
Operating Time
min
98
146
Charging Time
min
200
270
Weight
lb
275
300
(*) Measurement uncertainty KpA < 1.5 dB (A). Noise emission values obtained according to EN-60335-2-69
(**)
Total value of vibration output to the operator arm and hand
Dimensions
Figure 3
Model
VHB436
A (in)
41.3
B (in)
23.6
C (in)
49.2
[ NOTE ]
■
Storage conditions:
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
■
Operating conditions:
Maximum altitude: 800 m
(Up to 2,000 m with reduced performances)
Temperature: -10°C ÷ +40°C
Humidity: ≤ 85%
[ NOTE ]
If used at temperature below 0°C, battery life may not be as
long as stated.
Summary of Contents for VHB436
Page 2: ......
Page 46: ...C504 2 VHB436N 7 8 1 9 1 2 4 3 5 2 5 6 2 1 RED 3 GREEN...
Page 47: ...VHB436N 3 C504 10 2 3 4 1 3 5 6 11 1 50 mm...
Page 48: ...C504 4 VHB436N 1 3 4 2 3 2 1 1 6 4 5 12 15 1 2 14 13 4 1 3 2 1 2 16...
Page 50: ...C504 6 VHB436N 421925 UI MOTORHEAD 1 2 3 4 5 6...
Page 51: ......