909 6313 000(2)2007-06 A
SCRUBTEC 343B
19
USER MANUAL
ENGLISH
SOLUTION FILTER CLEANING
Empty the solution tank (32) as shown in the relevant paragraph.
Drive the machine on a level fl oor.
Make sure that the switches (65 and 66) are in the "0" position.
Remove the transparent cover (A, Fig. 8), then remove the fi lter strainer (B). Clean and install them on the support (C).
NOTE
The fi lter strainer (B) must be correctly positioned on the housing (D) of the support (C).
C
B
A
B
D
Figure 8
S310232A
MACHINE SPEED ADJUSTMENT
NOTE
The machine speed varies according to the type of fl oor to be cleaned and the choice of using the brush or the pad.
If necessary, perform the following procedure.
Remove the recovery water tank as shown in Use chapter.
Adjust the machine speed with the screw (53) as shown below:
Loosen the screw (57), on the right side of the machine, by turning it counter-clockwise.
Rotate the adjusting screw (53) counter-clockwise to increase the machine speed.
Turn the adjusting screw (53) clockwise to decrease the machine speed.
After adjusting, tighten the screw (57).
Install the recovery water tank as shown in Use chapter.
With the machine ready to operate, perform hands-on tests of the machine and, if other adjustments are necessary, repeat
steps 1 to 4.
1.
2.
3.
4.
1.
2.
•
•
•
•
3.
4.
Summary of Contents for SCRUBTEC 343B
Page 2: ......