9097058000(2)2009-10 A
SCRUBTEC 653B – 653BL – 651BCL – 661BL
27
USER MANUAL
ENGLISH
TANK AND VACUUM GRID WITH FLOAT CLEANING, AND COVER GASKET CHECK
Drive the machine to the appointed disposal area.
1.
Turn the ignition key (80) to “0”.
2.
Open the cover (A, Fig. 9) to washing position (L).
3.
Wash with clean water the cover (A), the tanks (B and C) and the vacuum grid with automatic shut-off
fl
oat (D).
4.
Drain the water from the tanks with the hoses (16 and 17).
5.
If necessary, release the fasteners (E) and open the grid (D), recover the
fl
oat (F), clean all the components and then reinstall
them.
Check the tank cover gasket (G) for integrity.
6.
NOTE
The gasket (G) creates vacuum in the tank that is necessary for vacuuming the recovery water.
If necessary replace the gasket (G) by removing it from its housing (H). When assembling the new gasket, install the joint (I) in
the rear central area, as shown in the
fi
gure.
Check that the seating surface (J) of the gasket (G) is integral and adequate for the gasket itself.
7.
NOTE
The hole (K), allowing to compensate the air in the cover air gap, contributes to create vacuum in the tank.
Close the cover (A).
8.
H
D
E
E
F
G
A
G
B
C
L
K
I
J
P100119
Figure 9