Solution System
112
Service Manual – SCRUBTEC R466 ... FOCUS II Micro Rider
Troubleshooting
Trouble
Possible Causes
Remedy
Small amount of solution or no solution
reaches the brush
The tank filter (optional) is clogged/dirty
Clean the filter
The solution filter is clogged/dirty
Clean the filter
The solution valve is closed/semi-closed
Replace the valve
The solenoid valve (EV1) is broken or there is an open in
the electrical connection
Replace the solenoid valve/repair
the electrical connection
There is debris in the solution/clean water tank clogging
the output hole
Clean the tank
There is debris in the solution/clean water hoses clogging
the flow
Clean the hoses
The function electronic board (EB1) is faulty
Replace
The display electronic board (EB2) is faulty
Replace
The dashboard electronic board (EB3) is faulty
Replace
The solution reaches the brush also
when the machine is off
There is dirt or calcium deposit on the solenoid valve
gaskets (EV1)
Clean the solenoid valve inner
gaskets
The solenoid valve (EV1) is broken
Replace the solenoid valve