4. Installation
4. Installation
.16.
.17.
Figure 4.17 Status indicator lights
4.7 LED Indicates
There are three LED indicators on the Solis AC Coupled inverter (Red, Green, and Orange)
which indicate the working status of the inverter.
Light
Status
Description
POWER
ON
The inverter can detect DC power.
OFF
No DC power.
OPERATION
ON
The inverter is fully operational.
OFF
The inverter has stopped operating.
FLASHING
The inverter is initializing.
ALARM
OFF
No fault condition detected.
FLASHING
Fault condition is detected.
4.8 Solis TechView Illustration
RAI series inverter can be controlled by LCD or APP
(Solis TechView). For IOS system, please go to AppStore
to search for "Solis TechView", then download and install it.
For Android system, please go to Google Play to search
for "Solis TechView", then download and install it.
Besides, it can be also installed by scanning the QR code
on the back cover of this manual.
To use the APP to control the inverter, you need to make
sure the inverter is operating and then use your mobile
device to connect the WiFi signal of the inverter
(Factory defaults is Solis - inverter SN, and initial
password is solis100. If any questions,
please refer to Solis TechView quick guide).
Then, you can enter the APP to view the information
and change the settings of the inverter.
Figure 4.18