07-02233A MANUAL - 1200MS 115V PORTABLE
3
Ninja
All repairs must be performed by a qualified service
person. Only parts approved by Legend Brands
should be used.
Cautions: Risk of property damage
CAUTION: Protect from freezing. Freezing may
damage internal components and will void warranty.
CAUTION: Do not use with water with over 3 grains
per gallon (51 miligrams per liter) of hardness. Use
with hard water could result in the formation of
mineral deposits inside pumps and fittings. Damage
caused by mineral deposits will void warranty.
CAUTION: Use only to extract moisture. Do not
immerse end of vacuum hose in liquid.
CAUTION: Do not use as a dry vacuum. Dust
particles will damage the vacuum motors. Damage
caused by dry vacuuming will void the warranty.
CAUTION: To prevent the growth of mold and
mildew inside the tanks, always drain waste tank
completely and empty solution tank after use.
WARRANTY
Visit
www.LegendBrandsCleaning.com
to register your
purchase. Registration allows us to better assist you with
using, maintaining or servicing your equipment, as well
as to contact you in case we have important safety
information concerning your product.
The warranty is valid from the date of purchase for one
year. This will cover parts and labor at an authorized
Ninja or Sapphire Scientific distributor. The warranty is
only valid to the original purchaser and proof of purchase
is required. Modifying this unit or not maintaining the
machine as outlined in this manual will void the warranty.
See the full Limited Warranty document for details.
GROUNDING INSTRUCTIONS
This appliance must be grounded. If it should
malfunction or break down, grounding provides a path of
least resistance for electric current to reduce the risk of
electric shock. This appliance is equipped with cords
having equipment-grounding conductors and grounding
plugs. The plugs must be inserted into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING! Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets
are properly grounded. Do not modify the plugs
provided with the appliance
– if the plugs do not fit
the outlets, have proper outlets installed by a
qualified electrician.
This equipment is for use on a circuit or circuits having a
nominal rating no more than 120V and is factory-
equipped with a specific electric cord and plug to permit
connection to a proper electric circuit. Make sure that the
appliance is connected to outlets having the same
configuration as the plugs. No adaptor should be used
with this appliance. If the appliance must be reconnected
for use on a different type of electric circuit, the
reconnection should be made by qualified service
personnel.
CONTROLS
ON THE CONTROL PANEL (Fig. 3)
Includes rocker-type switches control blower, solution
pump,
and pumpout (on select models).
ON THE BACK PANEL (Fig. 2H)
Pressure regulator.
Select models. Turn clockwise to
increase solution pressure; turn counterclockwise to
decrease solution pressure.
OPERATING INSTRUCTIONS
IMPORTANT: Make sure to control foaming in the
vacuum system. Excessive foam can allow moisture,
carpet fiber and other debris to be drawn through the
vacuum cutoff valve and cause damage to the vacuum
motors. Damage caused by moisture or debris will void
the product warranty. To help reduce foaming, use a
low-foam detergent. Foaming may also occur because of
residues left from previous cleanings. If this happens,
use a defoamer additive. Follow defoamer manufacturer
instructions for proper application.
NOTICE: The 1200MS model may contain
residual anti-freeze from the factory. Flush
pressure system with fresh water prior to first use.
WARNING: DO NOT drain used antifreeze on the
ground or into storm drains. Dispose of antifreeze
only in an approved location. Observe all relevant
laws when disposing anti-freeze.
1. Pre-mix cleaning solution with hot water in a
separate container. Pour mixed solution into the
solution tank of the machine or apply solution
directly to the cleaning surface as directed by
chemical manufacturer.
2. Connect vacuum and solution hoses to machine and
attach to extraction wand or hand tool.
3. Drain waste tank when full using gravity drain and
diverter (Fig. 7), or use the automatic pumpout
feature described below.
4. For
auto-fill operation
, attach fresh water supply to
freshwater inlet (Fig. 2J) and turn on water supply at
faucet. Tank will begin filling and automatically shut
off when full.
5. If
auto-pumpout operation
is desired, attach a
regular garden hose to auto-pumpout coupling (Fig.
2H), and place other end in suitable drain or large
container.
6. Insert both plugs into separate 3-pin grounded
circuits. Keep cords clear of your cleaning path.
The
1200MS unit has two cords and each cord should be
plugged into separate 3-pin grounded circuits. The
separate circuit indicator light will glow green (Fig.
2F) when the cords are properly connected.