Available Strobe parameter setting:
(1) Polarity setting
Tick Line Inverter to set polarity external trigger’s output signal, as shown in
Figure26
Figure 26.
Modifying Strobe Polarity
(2) Strobe valid time
As shown in Figure 27, Strobe is set to high level. When exposure starts, Strobe
will output immediately. Strobe Line Duration value decides the Strobe duration:
when the Strobe Line Duration value is 0, the Strobe duration is equal to the
exposure time;
when the Strobe Line Duration value is not 0, the Strobe duration is equal to
Strobe Line Duration value.
Figure 27.
Strobe Valid Electrical Level Duration
(3) Strobe output delay
The camera supports the function of Strobe signal output delay to satisfy special
application: as shown in Figure 28, when exposure starts, the Strobe output is not
valid immediately. Instead, the Strobe output will delay according to the setting in
Strobe Line Delay.