FastGene

®

 Plate Centrifuge   

 

 

Instruction Manual 

 

Catalog No. NG040 

 

   

 

 

 

 

 

 

 

www

.n

i

ppongenet

ics

.eu 

i

nfo@n

i

ppongenet

ics

.eu 

 

 

Ve

rsi

on 01 

20.01.2015 

DOMINIQUE DUTSCHER

Summary of Contents for FastGene NG040

Page 1: ...FastGene Plate Centrifuge Instruction Manual Catalog No NG040 www nippongenetics eu info nippongenetics eu Version 01 20 01 2015 D O M I N I Q U E D U T S C H E R ...

Page 2: ...1 Content 1x Plate Centrifuge 2x Adapter for 96 well plates 1x Power Cord 1x Instruction Manual D O M I N I Q U E D U T S C H E R ...

Page 3: ...Device Operation Instructions 9 4 1 Controls and Features 9 4 2 Turn On the Instrument 10 4 3 Operation Mode Quick Start Mode 10 4 4 Operation Mode Time mode 10 Section 5 Troubleshooting Guide 11 5 1 Problem and Solution 11 5 2 Maintenance 11 Section 6 Ordering information 11 Section 7 Warranty 12 D O M I N I Q U E D U T S C H E R ...

Page 4: ...maintenance and servicing Refer servicing to qualified personnel 5 Never use this instrument series without having the safety cover correctly in position 6 Do not use the unit if there is any sign of damage to the external tank or cover Replace damaged parts 7 Do not use in the presence of flammable or combustible material fire or explosion may result This device contains components which may igni...

Page 5: ...ons up to 10 of the normal voltage Avoiding Electrical Shock Follow the guidelines below to ensure safe operation of the unit FastGene Plate Centrifuge has been designed to use with shielded wires thus minimizing any potential shock hazard to the user Nippon Genetics Europe recommends against the use of unshielded wires To avoid electrical shock 1 In the event of solution accidentally spilled into...

Page 6: ...case of a single fault at least once per day 2 NEVER access dangerous chemicals or other materials to prevent possible hazard of explosion and damage 3 A temporary conductivity caused by condensation might occur even though this series is rated Pollution Degree 2 in accordance with IEC 664 Battery Replacement Notice The product may contain an internal manganese dioxide There is risk of fire and bu...

Page 7: ...ry or instrument damage ATTENTION Hot surface Indicates disposal instruction DO NOT throw this unit into a municipal trash bin when this unit has reached the end of its lifetime To ensure utmost protection of the global environment and minimize pollution please recycle this unit D O M I N I Q U E D U T S C H E R ...

Page 8: ...ug wrong 2 Preventative measures of risk Potential Risk Preventive measures Bruise Do not put the machine near the table edge Burn Cover the lid or wear insulated gloves Scald Cover the lid to avoid spray water or wear insulated gloves Drop Place the unit on a flat and dry surface Power cord plug wrong Observe correct adapter plug D O M I N I Q U E D U T S C H E R ...

Page 9: ...ding precise spinning control whether you need a PCR or an ELISA plate being centrifuged Small foot print Only a small lab bench space is needed Quick start Allows a one hand operation Section 2 Product Specifications Display LCD illuminated Maximum Centrifugation force 480 x g Timer 0 10 min Dimension L360 x W290 x H140mm Weight 3 6 kg Rated Voltages AC input 200V 240V 2A 50 60 Hz DC input 12V 5A...

Page 10: ...t is placed on a sturdy and level surface in a safe dry place and is inserted with equally heavy plates it is ready for operation Section 4 Device Operation Instructions 4 1 Controls and Features Please refer to below figures on the following page for the location of the different keys D O M I N I Q U E D U T S C H E R ...

Page 11: ... Switch the main power ON 4 3 Operation Mode Quick Start Mode 1 Switch the main power ON 2 Press the RUN STOP button to initiate the centrifugation 3 Stop pressing the RUN STOP button to finish the centrifugation 4 4 Operation Mode Time mode 1 Switch the main power ON 2 Press the Set button to adjust to the desired time 3 Press the RUN STOP button to initiate the centrifugation 4 Centrifugation wi...

Page 12: ...ase include a full description of the problem 5 1 Problem and Solution Problem Recommendations No signal on the screen 1 Check the FUSE 2 Ensure that the AC power switch is ON 3 Check the power cord is properly plugged into a grounded AC outlet with the appropriate voltage Fan Error Contact our service department or a distributor in your region 5 2 Maintenance Centrifuge chamber and rotors may be ...

Page 13: ...Genetics Europe s liability under the warranty is limited to the receipt of reasonable proof by the customer that the defect is embraced within the terms of the warranty All claims made under this warranty must be presented to Nippon Genetics Europe within one year following the date of delivery of the product to the customer Manufacturer Nippon Genetics Europe GmbH Address Binsfelder Straße 77 52...

Page 14: ...D O M I N I Q U E D U T S C H E R ...