183
10e
CHARGER
Equal LED (orange)
Stop button
Equal button
Reserve button
Reserve LED (green)
Auto button
Auto LED (green)
252W1017
<Checking of Total timer>
Checking procedure
Magnetic
contactor
Auto
LED
Reserve
LED
Equal
LED
1
Connect the battery plug.
OFF
2
Connect the AC plug to wall outlet.
OFF
3
Press and hold the Auto
Button for at least 5
seconds.
When
pressed
OFF
5 seconds later
ON
4
The check will end approximately 1 minute and
36 seconds after Auto Button begins flashing.
OFF
:On
:Off
:Flashing
l
From "
"(month & date), set the timer for 1 to 14 minutes later from the
current time. Make sure that the battery charging starts correctly at the set time.
(Refer to "10e-4-2. Reserve charge" on page 188 for more information.)
10e-3-3. Reserve function - inspection
10e-3-2. Earth - inspection
check the electric connection is done between the earth terminal and the body of the
receptacle of the charger panel. (0Ω by ×1 range of the tester)
CAN-BUS control
CAUTION
l
If the battery is just finished to charge, operate hydraulic function for 2 or 3
minutes to stabilize the battery voltage before starting to check the total timer.
l
If you interrupt to charge the batter y, push the "STOP" button before
disconnecting the battery plug to prevent from sparking.
l
For a fully charged battery, check after performing approximately 2-3 minutes
of hydraulic operation.
l
If the charging state LEDs are flashed, they will not turn off until the battery
plug is unplugged.
https://www.forkliftpdfmanuals.com/