220
SERVICE DATA
12
Group
Work
Job
Rate (hour)
10P-18P 20P-28P
30P
Directional
switch
R/R/I
Indicator panel cover
0.4
0.4
0.4
Cam comp.
0.2
0.2
0.2
Lever comp.
0.3
0.3
0.3
Microswitch
Add 0.1Hrs every time 1 piece is
added
0.2
0.2
0.2
Monthly inspection
Each connected area jolt
Lever movement condition
Microswitch timing and
operating condition
Microswitch damage, looseness
in mounting area
0.1
0.1
0.1
Yearly inspection
Adequacy of Microswitch
timing,damage, and fitting bolt
looseness
0.2
0.2
0.2
Indicator panel
R/R/I
Indicator panel cover
0.4
0.4
0.4
LCD display unit
0.3
0.3
0.3
Turn signal lamp switch
0.3
0.3
0.3
Sheet switch comp.
0.3
0.3
0.3
Display board
0.3
0.3
0.3
Monthly inspection
Turn signal lamp damage,
operating condition, and
mounting condition
Instruments operation
0.1
0.1
0.1
Main contactor
R/R/I
Contactor comp.
0.4
0.4
0.4
Yearly inspection
Contact point looseness,
damage, wear, operation,
fouling, and fitting bolt
looseness
0.1
0.1
0.1
Contactor
Monthly inspection
Contactor timing and operating
condition
0.1
0.1
0.1
Contactor contact point
looseness, damage, and wear
0.1
0.1
0.1
Contactor auxiliary contact point
wear, and damage
0.1
0.1
0.1
https://www.forkliftpdfmanuals.com/