69
Temperature during short duration transport
Applicable motor
Our gear motor
APQ series (200 V)
0.1 kW
0.2 kW
0.4 kW
0.75 kW
9. Product specifications
Item
Model
Remarks
0.1 kW
0.2 kW
0.4 kW
0.75 kW
Rated output current
0.6 A
0.9 A
2.0 A
3.8 A
O
u
t
p
u
t
Rated output capacity
0.3 kVA
0.6 kVA
1.1 kVA
1.9 kVA
Maximum output current
1.2 A
1.8 A
4.0 A
7.6 A
Maximum output voltage
Three-phase 200 to 240 V
P
o
w
e
r
s
u
p
p
l
y
Rated voltage and frequency
Three-phase/Single phase 200 to 240 V
50/60 Hz
Allowable voltage fluctuation
4.7 A
Single phase
1.7 A
2.5 A
4.6 A
-15 to +10%
Allowable frequency fluctuation
±5%
Rated input
current
Three-phase
1.1 A
1.6 A
2.7 A
Protective structure
Mounting inside a panel (IP20) and enclosed wall-mounted type
Cooling system
Auto cooling
Acceleration and deceleration
time
0.00 to 5.00 seconds Setting acceleration and deceleration
individually
* Maximum four points of each, switching selection by external
terminal
Torque limit
Switching selection method (Selection by setting the command
source)
▪ Digital command: Constant settings (maximum 8 points)
* Switching selection by external terminal
▪ Analog command: External terminal 0 to 10 V input
Set by command setting volume
[Resolution]
▪ Analog command and command
setting volume: Maximum torque
limit value 1/1023%
▪ Digital command: 1%
C
o
n
t
r
o
l
c
h
a
r
a
c
t
e
r
i
s
t
i
c
s
Control method
Sine wave PWM method
Carrier frequency 8 kHz
Speed control range
100 to 3000 r/min
Speed command settings
Switching selection method (Selection by setting the command
source)
▪ Digital command: Constant settings (maximum 16 points)
* Switching selection by external terminal
▪ Analog command: External terminal 0 to 10 V input
Set by command setting volume
[Resolution]
▪ Analog command and command
setting volume: Maximum rotational
speed 1/1023 r/min
▪ Digital command: 1 r/min
Mounting location
Indoor (Places without corrosive gas and dust)
Altitude
1000 m or less
Vibration
9.8 m/s
2
(1G) is allowed for 10 to 19 Hz, and
2.0 m/s
2
(0.2G) is allowed for 20 to 50 Hz
E
n
v
i
r
o
n
m
e
n
t
Ambient temperature
Mounting inside a panel: -10 to +50°C
Enclosed wall-mounted type: -10 to +45°C (Do not freeze)
Humidity
95% RH or less (Do not condensate)
Storage temperature
-20 to +60
0
C
Restriction of Hazardous Substances
command (ROHS command)
Supports