73
11. Standards Compliance
11-1. Compliance with CE Marking
(1) Low Voltage Directive
This driver is tested in accordance with following European standard, and complies
with Low Voltage Directive.
Applicable standard : EN61800-5-1
:
2007
Overvoltage category
:
Ⅱ
Pollution degree
:
2
Protection Class
:
1
・
Install fast blow fuse to the input side.
・
Only basic insulation is provided with control circuit terminals. Additional insulation
may be necessary in the end product to conform to CE requirements.
(2) EMC Directive
This driver is tested in accordance with European standards EN61800-3
:
2004, and
complies with EMC Directive. The following conditions must be met to ensure
continued compliance with EMC Directive.
・
Ground the drive enclosure.
・
Install the EMC noise filter to the input side.
・
Use shield cable or install cut core for motor power cable.
11-2. Compliance with UL Standard
This driver is tested in accordance with UL standard UL508C, and complies with UL
requirements. To ensure continued compliance when using this drive in combination
with other equipment, meet the following conditions.
(1) Compliance with Installation
・
This driver must be installed in a panel, and used within the ambient temperature
specification. (Maximum Surrounding Air Temperature 50
℃
)
・
Do not install the driver to an area greater than pollution degree 2.
・
Motor over temperature protection is not provided by the drive.
(2) Recommended Peripheral devices
・
Integral solid state short circuit protection does not provide branch circuit
protection. Branch circuit protection fuse specified in this manual must be provided
in accordance with the National Electrical Code and any additional local codes.
・
Suitable for use on a circuit capable of delivering not more than 5,000 Arms
symmetrical ampare, 240 volts maximum, when protected by UL Class J fuse with
following rating of ampare.
(3) Overload Protection Level
The driver has the following overload protection functions.
・
Stop with more than 450% of rated output current.
・
Stop with more than 100% of rated output current for 10 seconds,
or stop because of electronic thermal. (Option through the constant.)
A-BLPQ020T2
3A
A-BLPQ040T2
6A
A-BLPQ075T2
10A
・
In order to come under overvoltage category
Ⅱ
, insert an insulation transformer
Model
Current
(UL Listed Class J Fuse)
A-BLPQ010T2
3A