Operation
Testing of Functionality
Provided with the ST730
T
are two cable samples with different insulation thicknesses. One end of
each cable was stripped with the machine for testing at the factory. The respective stripping values
are stored in programs Cable 1, Cable 2, Cable 3 (for the thinner cable) and Cable 4 and Cable 5
(for the thicker cable). The stripping quality of the ST730
T
can be tested as follows:
Program Step
Selecting
and Entering
Select cable No.1
Cable -
1
- Enter
-
•
Place the thinner sample cable with the non-stripped end through the jaws (4) until it touches
the trigger plate (9). As soon as the cable touches the plate the stripping process is initiated
based on the data set at the factory.
•
The thin sample cable can be stripped applying
different stripping sequences; for this purpose press the button sequence Cable 2 or Cable 3.
•
Proceed with processing of the thicker cable, by selecting Cable 4 and Cable 5 in the same
manner as described above.
Fig. 6. Stripping of sample cable